Advantage
• Provide a complete verification manual to facilitate compliance with pharmaceutical/electronic specifications.
• Built-in thermal printer for sampling data printing.
• Support long-term data storage and USB export.
• Light weight and ergonomic design suitable for one person to operate.
• Audit tracking, personnel operation record storage.
• The particle number alarm is realized by setting the alarm parameters.
• Set up separate passwords and operation permissions according to the identity of operator, auditor and administrator.
• Sampling area, grade standard and particle size selection can be preset in advance.
• GMP and ISO 14644-1 cleanliness standard judgment.
• It was verified according to JJF 1190-2008 and GB/T 6167-2007.
• 7-inch touch screen, simplified operation.
• Support RS485: Modbus RTU protocol, Ethernet:Modbus TCP/IP protocol.
Function
Apply
Model | SX-L301A | SX-L310A | SX-L3100AL | |
Sampling flow | 2.83L/min±5%(0.1CFM) | 28.3L/min±5%(1.0 CFM) | 100L/min±5%(3.53 CFM) | |
Particle size channel | 0.3μm, 0.5μm, 1.0μm, 5.0μm, 10.0μm, 25.0μm can be screened | |||
Laser light source | Imported laser diodes (continuous life up to 100,000 hours) | |||
Vacuum power source | DC air pump, continuous working flow stable, energy-saving and environmentally friendly, efficient and low-noise | |||
Verification criteria | JJF1190-2008,GB/T6167-2007 | |||
Relative error of repeatability | ≤10%FS | |||
Particle size distribution error | ≤30% | |||
Particle concentration indication error | ≤±30%FS | |||
Self-cleaning time | ≤10min (counting is zero for 3 consecutive times within 10 minutes) | |||
Sampling time | User set (1~14400 seconds) | |||
Sampling delay | User set (1~255 seconds) | |||
District management | You can preset 1000 sampling areas and save the configuration parameters independently | |||
Number of sampling points | l~250 | |||
Number of samples (per point) | 1~50 | |||
Point spacing | Manual/automatic (0 to 14,400 seconds) | |||
Sampling concentration | 35,000 particles /L | |||
Counting mode | Cumulative number, concentration (m³, ft³) | |||
Data memory capacity | 5 million ordinary sampling data, 1 million UCL sampling data, and 10 million audit tracking data | |||
Cleanliness grade judgment criteria | ISO 14644.1-1999, GMP dynamic, GMP static, GB/T 25915.1-2021, YY/T 0033-2000 | |||
Operate time | The continuous test time after full charge is more than 8 hours | |||
Authority management | Three levels of permission, data storage and retrieval, printing | |||
Power supply | DC25.2V 5A | |||
Other accessories | Equal power sampling frame, data U disk, network cable, communication terminal, exhaust port, wifi antenna | |||
Environmental requirements | Usage environment: temperature 0~40℃ relative humidity 10~70% | |||
Storage environment: temperature-30℃~45℃ relative humidity 0~90% | ||||
Outline dimension | 210.5 long x 195 wide x 231 thick (mm) excluding sampling port | 242 long x 195 wide x 286 thick (mm) excluding sampling port | ||
Exterior material | SUS316L stainless steel | |||
Weight | 4.6kg | 4.6kg | 6.0kg | |
Power | Counter (15W), charger (126W) | Counter (75W), charger (126W) | ||
Quality Assurance | The warranty is 1 year, and optional extended warranty service is available |