Airborne Microbial Sampler

The SX-JCQ-2 sampler is an efficient porous suction sampler based on the Anderson impact principle, with an impact velocity of 10.8m/s. The suction device of the instrument directly sucks in microbial particles through micropores and impacts them onto the agar plate through a porous sampling head. After the collection is completed, cover the agar culture dish and perform colony cultivation and colony calculation.

Product Details
Product Videos

The SX-JCQ-2 sampler is an efficient porous suction sampler based on the Anderson impact principle, with an impact velocity of 10.8m/s. The suction device of the instrument directly sucks in microbial particles through micropores and impacts them onto the agar plate through a porous sampling head. After the collection is completed, cover the agar culture dish and perform colony cultivation and colony calculation.
The SX-JCQ-2 is equipped with an efficient suction device that can continuously monitor the suction process. The system measures air and regulates the inflow inhalation volume to maintain 28.3L or 50L. It ensures the microbial impact rate to achieve the highest capture rate. When external factors prevent or disrupt stable flow, the instrument's automatic wind speed adjustment device will ensure stable flow. The sampler is separate from the collection fan and must ensure good air tightness.



Advantage

• Flow closed-loop self-regulation with an error of ± 2.5%.
• DC power supply, safe and convenient.
• Supporting upper computer software to ensure data storage integrity.
• 316 sampling head, supporting multiple sterilization methods.
• Low noise, providing a comfortable working environment.


Function

• The flow control device will ensure the sampling flow rate
• Ensure impact velocity
• Compliant with ISO 14698-1/2 standard


Apply

• Microbial air sampling in cleanrooms and related controlled environments
• Microbial sampling control
• Microbial monitoring in the production environment of medical equipment

Technical Specifications
Model SX-JCQ-2
Sample flow 28.3 or 50L/min optional
Single sampling quantity Set by the upper computer software
Sample delay Set by the upper computer software
Mueller-Hinton agar Φ90mm × 15mm
Gas source Domestic fan
Compliant with standards GMP、 ISO 14698-1/2、GB/T 16293-2010
Power supply 220v/50hz
Flow regulation The flow can be automatically adjusted
Communication method Modbus RTU and Modbus TCP/IP
Environment requirements Usage environment: Temperature 0~40 ℃, relative humidity 10~70% RH
Storage environment: Temperature -30~45 ℃, relative humidity 0~90% RH
External dimensions Length 242.5 x Width 182 x Height 120 (mm)
Material 304 stainless steel material
Power ≤0.2KW
Weight 3.25kg
Warranty 1-year warranty, optional extended warranty service

Submit the form below to contact us now.