The instrument is user-friendly, with a simple operation and a user-friendly interface, enabling efficient and effective detection of suspended particles in clean environments. It is the preferred choice for rapid testing of cleanroom cleanliness in industries such as biopharmaceuticals, electronics, semiconductors, and new energy.
Advantage
• Provide a complete verification manual to facilitate
compliance with pharmaceutical/electronic specifications.
• Built-in thermal printer for sampling data printing.
• Support long-term data storage and USB export.
• Light weight and ergonomic design suitable for one person to operate.
• Audit tracking, personnel operation record storage.
• The particle number alarm is realized by setting the
alarm parameters.
• Set up separate passwords and operation permissions according to the identity of operator, auditor and administrator.
• Sampling area, grade standard and particle size
selection can be preset in advance.
• GMP and ISO 14644-1 cleanliness standard judgment.
• It was verified according to JJF 1190-2008 and GB/T
6167-2007.
• 7-inch touch screen, simplified operation.
• Support RS485: Modbus RTU protocol, Ethernet:Modbus TCP/IP protocol.
Function
• 5 million ordinary sampling data, 1 million UCL sampling data, and 10 million audit tracking data
Apply
Model | SX-L301A | SX-L310A | SX-L3100AL | |
Sampling flow | 2.83L/min±5%(0.1CFM) | 28.3L/min±5%(1.0 CFM) | 100L/min±5%(3.53 CFM) | |
Particle size channel | 0.3μm, 0.5μm, 1.0μm, 5.0μm, 10.0μm, 25.0μm can be screened | |||
Laser light source | Imported laser diodes (continuous life up to 100,000 hours) | |||
Vacuum power source | DC air pump, continuous working flow stable, energy-saving and environmentally friendly, efficient and low-noise | |||
Verification criteria | JJF1190-2008,GB/T6167-2007 | |||
Relative error of repeatability | ≤10%FS | |||
Particle size distribution error | ≤30% | |||
Particle concentration indication error | ≤±30%FS | |||
Self-cleaning time | ≤10min (counting is zero for 3 consecutive times within 10 minutes) | |||
Sampling time | User set (1~14400 seconds) | |||
Sampling delay | User set (1~255 seconds) | |||
District management | You can preset 1000 sampling areas and save the configuration parameters independently | |||
Number of sampling points | 1~250 | |||
Number of samples (per point) | 1~50 | |||
Point spacing | Manual/automatic (0 to 14,400 seconds) | |||
Sampling concentration | 35,000 particles /L | |||
Counting mode | Cumulative number, concentration (m³, ft³) | |||
Data memory capacity | 5 million ordinary sampling data, 1 million UCL sampling data, and 10 million audit tracking data | |||
Cleanliness grade judgment criteria | ISO 14644.1-1999, GMP dynamic, GMP static, GB/T 25915.1-2021, YY/T 0033-2000 | |||
Operate time | The continuous test time after full charge is more than 8 hours | |||
Authority management | Three levels of permission, data storage and retrieval, printing | |||
Power supply | DC25.2V 5A | |||
Other accessories | Equal power sampling frame, data U disk, network cable, communication terminal, exhaust port, wifi antenna | |||
Environmental requirements | Usage environment: temperature 0~40℃ relative humidity 10~70% | |||
Storage environment: temperature-30℃~45℃ relative humidity 0~90% | ||||
Outline dimension | 210.5 long x 195 wide x 231 thick (mm) excluding sampling port | 242 long x 195 wide x 286 thick (mm) excluding sampling port | ||
Exterior material | SUS316L stainless steel | |||
Weight | 4.6kg | 4.6kg | 6.0kg | |
Power | Counter (15W), charger (126W) | Counter (75W), charger (126W) | ||
Quality Assurance | The warranty is 1 year, and optional extended warranty service is available |